Duration
104 weeks
(88 weeks tuition + 16 weeks break)
Location
QLD Campus
Tuition Fee
Offshore Int Student: $34,000*
Onshore Student Visa Holder: $30,000*
*Non-Tuition Fees not included
We are currently updating our website
104 weeks
(88 weeks tuition + 16 weeks break)
QLD Campus
Offshore Int Student: $34,000*
Onshore Student Visa Holder: $30,000*
UEE62520 – Advanced Diploma of Air Conditioning and Refrigeration Engineering provides competencies to design and validate/evaluate refrigeration and air conditioning equipment and systems, manage risk, estimate and manage projects and provide technical advice/sales. It includes regulatory requirements for purchasing and handling refrigerants.
It develops competencies in the ethical and responsible application of mathematics, science, engineering techniques, standards and codes of practice, engineering design practices, supervision and management of physical, human and financial resources in refrigeration and air conditioning engineering.
Pre-Enrolment Information
Prior to enrolment, it is mandatory that students attend a Pre-Enrolment Consultation with one of our approved Education Agents or delegated AIBT staff.
A Pre-Enrolment Consultation session may be provided to a prospective student one or more times to provide the prospective student additional time and/or information to make an informed decision. In addition, the communication channels used for conducting Pre-Enrolment Consultation sessions can be in various forms such as Face-To-Face, Video Conference, telephone call, and email.
Students will be provided with clear and accurate information about their course before enrolment to allow students to make an informed decision.
During this Pre-Enrolment Consultation session, prospective students will be provided with all the relevant course information to help guide them to make a formal decision that will reflect their existing skills and competencies and meet their needs. International students will be provided with a Pre-Enrolment Consultation Checklist and Handout to ensure they understand the support services provided and their obligations as an international student.
International students should ensure that they have read the Pre-Enrolment Consultation Checklist and Handout available on the ‘How to Apply’ page under the ‘Get Started’ tab on this website.
Please Note:
Blended Delivery (NSW | QLD)
This qualification will be provided by face-to-face training session at the college, workshop facility, and online live webinar training via a web-hosted online training service (e.g., Microsoft Teams, GoToMeeting). However, in any special circumstances, the mode of delivery can be adjusted reasonably and fair to the client cohorts.
Student visa holders are required to attend a minimum of 20 scheduled course contact hours per week.
The mode of delivery of RPL candidates depends on the process and outcome of the RPL. The candidates can refer to the process of RPL from the Recognition of prior learning (RPL) Information Kit – RPL Kit and RPL Strategy. For more information, please contact student support at studentsupport@aibtglobal.edu.au
Tech Science Workshop (NSW)
Unit 7, 9A Foundry Road
Seven Hills NSW 2147
Tech Science Workshop (QLD)
Unit 7, 27 Selhurst Street
Coopers Plains Qld 4108
Tech Science Workshop (TAS)
Unit 1, 22 Maxwells Road
Cambridge TAS 7170
AIBT – Monthly intakes except June and December
Study Period
In a year, there are two study periods*:
*Note: Students may be required to continue their study during the June break and December break. The study classes in June and December can be arranged due to special circumstances (e.g., lack of academic progress or under the intervention strategy plan.)
Preprare to work safely in the construction industry
Please note all electives are pre-selected by AIBT.
For more information on the course content, visit:
training.gov.au/Training/Details/UEE62520
This qualification must be delivered as per the packaging rules, even if a core unit/named elective has been superseded, until such time as the qualification has been updated and this update is reflected on the National Register, training.gov.au, and is listed on the RTO’s Scope of Registration. There are many situations where it is considered beneficial for the student to receive the updated training that reflects the current skill needs of the relevant industry so a provider may choose to deliver the updated unit, issue a statement of attainment for those unit/s and then provide credit transfer – by mapping backwards – to the units named within the qualification.
If this still does not ascertain a ‘competent’ result, the student may need to undertake gap training against the destination qualification. |
A minimum of IELTS 5.5 or equivalent is required.
For more information regarding the commonly acceptable types of English language proficiency evidence, along with the verification methods, please click here
International Students who do not meet the English language requirements for this course may undertake English Language Intensive Course for Overseas Students (ELICOS) according to the English Learning Matrix.
Diploma of Air-conditioning and Refrigeration Servicing (UEE51211)
The following Pre-requisites are required for this qualification.
UEENEEE101A | Apply Occupational Health Safety regulations, codes and practices in the workplace | There are no prerequisite competencies for this unit |
UEENEEE101A | Apply Occupational Health Safety regulations, codes and practices in the workplace | There are no prerequisite competencies for this unit |
UEENEED102A | Assemble, set-up and test computing devices | UEENEEE101A Apply Occupational Health Safety regulations, codes and practices in the workplace |
UEENEEE105A | Fix and secure electrotechnology equipment | UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace |
UEENEEE107A | Use drawings, diagrams, schedules, standards, codes and specifications | UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace |
UEENEEE137A | Document and apply measures to control OHS risks associated with electrotechnology work | UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace |
UEENEEE011C | Manage risk in electrotechnology activities | There are no prerequisite competencies for this unit |
UEENEEE080A | Apply industry and community standards to engineering activities/td> | UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace |
UEENEEE083A | Apply industry and community standards to engineering activities | There are no prerequisite competencies for this unit. |
UEENEEJ040B | Manage refrigeration and air conditioning projects | There are no prerequisite competencies for this unit. |
UEENEEJ069B | Plan refrigeration and air conditioning projects | There are no prerequisite competencies for this unit. |
UEENEEJ128A | Produce HVAC/R system design drawings | UEENEEJ164A Analyse the operation of HVAC air and hydronic systems UEENEEJ192A Analyse the psychrometric performance of HVAC/R systems UEENEEJ193A Analyse the thermodynamic performance of HVAC/R systems OR UEENEEJ109A Verify functionality and compliance of refrigeration and air conditioning installations UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace UEENEEE102A Fabricate, assemble and dismantle utilities industry components UEENEEE003B Solve problems in extra-low voltage single path circuits UEENEEE105A Fix and secure electrotechnology equipment UEENEEE107A Use drawings, diagrams, schedules, standards, codes and specifications UEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology work UEENEEJ102A Prepare and connect refrigerant tubing and fittings UEENEEJ103A Establish the basic operating conditions of vapour compression systems UEENEEJ104A Establish the basic operating conditions of air conditioning systems UEENEEJ106A Install refrigerant pipe work, flow controls and accessories UEENEEJ107A Install air conditioning and refrigeration systems, major components and associated equipment UEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerants UEENEEJ110A Select refrigerant piping, accessories and associated controls UEENEEJ111A Diagnose and rectify faults in air conditioning and refrigeration systems and components UEENEEJ113A Commission air conditioning and refrigeration systems UEENEEJ153A Find and rectify faults motors and associated controls in refrigeration and air conditioning systems UEENEEJ170A Diagnose and rectify faults in air conditioning and refrigeration control systems UEENEEJ194A Solve problems in low voltage refrigeration circuits UEENEEP012A Disconnect / reconnect composite appliances connected to low voltage installation wiring UEENEEP017A Locate and rectify faults in low voltage composite appliances using set procedures UEENEEP024A Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply UEENEEP025A Attach cords, cables and plugs to electrical equipment for connection to 1000 Va.c. or 1500 Vd.c. supply. |
UEENEEJ102A | Prepare and connect refrigerant tubing and fittings | UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace |
UEENEEJ103A | Establish the basic operating conditions of vapour compression systems | UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace |
UEENEEJ104A | Establish the basic operating conditions of air conditioning systems | UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace |
UEENEEJ106A | Install refrigerant pipe work, flow controls and accessories | UEENEEE102A Fabricate, assemble and dismantle utilities industry componentsUEENEEE105A Fix and secure electrotechnology equipmentUEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology workUEENEEJ102A Prepare and connect refrigerant tubing and fittingsUEENEEJ103A Establish the basic operating conditions of vapour compression systemsUEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace |
UEENEEJ107A | Install air conditioning and refrigeration systems, major components and associated equipment | UEENEEJ106A Install refrigerant pipe work, flow controls and accessoriesUEENEEJ170A Diagnose and rectify faults in air conditioning and refrigeration control systemsUEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplaceUEENEEE102A Fabricate, assemble and dismantle utilities industry componentsUEENEEE105A Fix and secure electrotechnology equipmentUEENEEE107A Use drawings, diagrams, schedules, standards, codes and specificationsUEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology work UEENEEJ102A UEENEEJ103A UEENEEJ108A UEENEEJ194A UEENEEJ153A |
UEENEEJ108A | Recover, pressure test, evacuate, charge and leak test refrigerants | UEENEEJ102A Prepare and connect refrigerant tubing and fittings UEENEEJ103A Establish the basic operating conditions of vapour compression systems UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace |
UEENEEJ109A | Verify functionality and compliance of refrigeration and air conditioning installations | UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplaceUEENEEE102A Fabricate, assemble and dismantle electro componentsUEENEEE003B Solve problems in extra-low voltage single path circuitsUEENEEE105A Fix and secure electrotechnology equipmentUEENEEE107A Use drawings, diagrams, schedules, codes and manualsUEENEEE137A Document occupational hazards and risksUEENEEJ102A Prepare and connect refrigeration tubing and fittings UEENEEJ103A UEENEEJ104A UEENEEJ106A UEENEEJ107A UEENEEJ108A UEENEEJ110A UEENEEJ111A UEENEEJ113A UEENEEJ153A UEENEEJ170A UEENEEJ194A UEENEEP012A UEENEEP017A Locate and rectify faults in low voltage composite appliances using set procedures UEENEEP024A Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply UEENEEP025A Attach cords, cables and plugs to electrical equipment for connection to 1000 Va.c. or 1500 Vd.c. supply |
UEENEEJ110A | Select refrigerant piping, accessories and associated controls | UEENEEJ103A Establish the basic operating conditions of vapour compression systems UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace |
UEENEEJ111A | Diagnose and rectify faults in air conditioning and refrigeration systems and components | UEENEEJ107A Install air conditioning and refrigeration systems, major components and associated equipment UEENEEJ110A Select refrigerant piping, accessories and associated controls UEENEEP017A Locate and rectify faults in low voltage composite appliances using set proceduresUEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplaceUEENEEE102A Fabricate, assemble and dismantle utilities industry componentsUEENEEE003B Solve problems in extra-low voltage single path circuitsUEENEEE105A Fix and secure electrotechnology equipmentUEENEEE107A Use drawings, diagrams, schedules, standards, codes and specificationsUEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology work UEENEEJ102A UEENEEJ103A UEENEEJ104A UEENEEJ106A UEENEEJ108A UEENEEJ153A UEENEEJ194A Solve problems in low voltage refrigeration circuits UEENEEJ170A Diagnose and rectify faults in air conditioning and refrigeration control systems UEENEEP012A Disconnect / reconnect composite appliances connected to low voltage installation wiring |
UEENEEJ113A | Commission air conditioning and refrigeration systems | UEENEEJ107A Install air conditioning and refrigeration systemsUEENEEJ110A Select refrigerant piping, accessories & controlsUEENEEP017A Locate and rectify faults in low voltage composite appliances using set proceduresUEENEEE101A Apply Occupational Health and Safety regulationsUEENEEE102A Fabricate, assemble and dismantle utilities industry componentsUEENEEE003B Solve problems in extra-low voltage single path circuitsUEENEEE105A Fix and secure electrotechnology equipment UEENEEE107A UEENEEE137A UEENEEJ102A UEENEEJ103A UEENEEJ104A UEENEEJ106A UEENEEJ107A UEENEEJ108A UEENEEJ170A UEENEEJ194A UEENEEP012A UEENEEP017A |
UEENEEJ153A | Find and rectify faults in motors and associated controls in refrigeration and air conditioning systems | UEENEEE107A Use drawings, diagrams, schedules, standards, codes and specifications UEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerantsUEENEEJ194A Solve problems in low voltage refrigeration circuitsUEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplaceUEENEEE003B Solve problems in extra-low voltage single path circuitsUEENEEJ103A Establish the basic operating conditions of vapour compression systems |
UEENEEJ170A | Diagnose and rectify faults in air conditioning and refrigeration control systems | UEENEEJ153A Find and rectify faults motors and associated controls in refrigeration and air conditioning systems UEENEEE107A Use drawings, diagrams, schedules, standards, codes and specifications UEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerants UEENEEJ194A Solve problems in low voltage refrigeration circuits UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace UEENEEE003B Solve problems in extra-low voltage single path circuits |
UEENEEJ194A | Solve problems in low voltage refrigeration circuits | UEENEEE103A Solve problems in ELV single path circuits andUEENEEJ103A Establish the basic operating conditions of vapour compression systemsandUEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplaceorUEENEEJ195A Establish the basic operating conditions of vapour compression systems – appliancesand UEENEEE101A |
UEENEEK142A | Apply environmentally and sustainable procedures in the energy sector | There are no prerequisite competencies for this unit |
UEENEEP012A | Disconnect / reconnect composite appliances connected to low voltage installation wiring | There are no prerequisite competencies for this unit |
UEENEEP017A | Locate and rectify faults in low voltage composite appliances using set procedures | UEENEEP012A Disconnect / reconnect composite appliances connected to low voltage installation wiring |
UEENEEP024A | Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply | UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace |
UEENEEP025A | Attach cords, cables and plugs to electrical equipment for connection to 1000 Va.c. or 1500 Vd.c. supply | UEENEEP024A Attach cords and plugs to electrical equipment for connection to a single phase 230 volt supply |
UEENEE103A | Solve problems in ELV single path circuits | UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace |
UEENEE117A | Implement and monitor energy sector OHS policies and procedures | There are no prerequisite competencies for this unit. |
UEENEEE124A | Compile and produce an energy sector detailed reports | There are no prerequisite competencies for this unit. |
UEENEEJ127A | Establish the thermodynamic parameters of refrigeration and air conditioning systems | UEENEEJ192A Analyse the psychrometric performance of HVAC/R systemsUEENEEJ193A Analyse the thermodynamic performance of HVAC/R systemsORUEENEEJ109A Verify functionality and compliance of refrigeration and air conditioning installationsUEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplaceUEENEEE102A Fabricate, assemble and dismantle utilities industry componentsUEENEEE003B Solve problems in extra-low voltage single path circuits UEENEEE105A UEENEEE107A UEENEEE137A UEENEEJ102A UEENEEJ103A UEENEEJ104A UEENEEJ106A UEENEEJ107A UEENEEJ108A UEENEEJ110A UEENEEJ111A UEENEEJ113A UEENEEJ153A UEENEEJ170A UEENEEJ194A UEENEEP012A UEENEEP017A UEENEEP024A UEENEEP025A |
UEENEEJ129A | Establish heat loads for commercial refrigeration and/or air conditioning applications | UEENEEJ127A Establish the thermodynamic parameters of refrigeration and air conditioning systems UEENEEJ192A and UEENEEJ193A or UEENEEJ109A UEENEEE101A UEENEEE102A UEENEEE003B UEENEEE105A UEENEEE107A UEENEEE137A UEENEEJ102A UEENEEJ103A UEENEEJ104A UEENEEJ106A UEENEEJ107A UEENEEJ108A UEENEEJ110A UEENEEJ111A UEENEEJ113A UEENEEJ153A UEENEEJ170A UEENEEJ194A UEENEEP012A UEENEEP017A UEENEEP024A UEENEEP025A |
UEENEEJ164A | Analyse the operation of HVAC air and hydronic systems | UEENEEJ192A Analyse the psychrometric performance of HVAC/R systemsUEENEEJ193A Analyse the thermodynamic performance of HVAC/R systemsorUEENEEJ109A Verify functionality and compliance of refrigeration and air conditioning installationsUEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplaceUEENEEE102A Fabricate, assemble and dismantle utilities industry componentsUEENEEE003B Solve problems in extra-low voltage single path circuitsUEENEEE105A Fix and secure electrotechnology equipment UEENEEE107A UEENEEE137A UEENEEJ102A UEENEEJ103A UEENEEJ104A UEENEEJ106A UEENEEJ107A UEENEEJ108A UEENEEJ110A UEENEEJ111A UEENEEJ113A UEENEEJ153A UEENEEJ170A UEENEEJ194A UEENEEP012A UEENEEP017A UEENEEP024A UEENEEP025A |
UEENEEJ165A | Evaluate thermodynamic and fluid parameters of refrigeration systems | UEENEEJ127A Establish the thermodynamic parameters of refrigeration and air conditioning systemsUEENEEJ164A Analyse the operation of HVAC air and hydronic systemsUEENEEJ192A Analyse the psychrometric performance of HVAC/R systemsandUEENEEJ193A 0r Analyse the thermodynamic performance of HVAC/R systemsUEENEEJ109A Verify functionality and compliance of refrigeration and air conditioning installationsUEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplaceUEENEEE102A Fabricate, assemble and dismantle utilities industry components UEENEEE003B UEENEEE105A UEENEEE107A UEENEEE137A UEENEEJ102A UEENEEJ103A UEENEEJ104A UEENEEJ106A UEENEEJ107A UEENEEJ108A UEENEEJ110A UEENEEJ111A UEENEEJ113A UEENEEJ153A UEENEEJ170A UEENEEJ194A UEENEEP012A UEENEEP017A UEENEEP024A UEENEEP025A |
UEENEEJ192A | Analyse the psychrometric performance of HVAC/R systems | UEENEEJ193A Analyse the thermodynamic performance of HVAC/R systems or UEENEEJ109A Verify functionality and compliance of refrigeration and air conditioning installations UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace UEENEEE102A Fabricate, assemble and dismantle utilities industry components UEENEEE103A Solve problems in ELV single path circuits UEENEEE105A Fix and secure electrotechnology equipment UEENEEE107A Use drawings, diagrams, schedules, standards, codes and specifications UEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology work UEENEEJ102A Prepare and connect refrigerant tubing and fittings UEENEEJ103A Establish the basic operating conditions of vapour compression systems UEENEEJ104A Establish the basic operating conditions of air conditioning systems UEENEEJ106A Install refrigerant pipe work, flow controls and accessories UEENEEJ107A Install air conditioning and refrigeration systems, major components and associated equipment UEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerants UEENEEJ110A Select refrigerant piping, accessories and associated controls UEENEEJ111A Diagnose and rectify faults in air conditioning and refrigeration systems and components UEENEEJ113A Commission air conditioning and refrigeration systems UEENEEJ153A Find and rectify faults motors and associated controls in refrigeration and air conditioning systems UEENEEJ170A Diagnose and rectify faults in air conditioning and refrigeration control systems UEENEEJ194A Solve problems in low voltage refrigeration circuits UEENEEP012A Disconnect / reconnect composite appliances connected to low voltage installation wiring UEENEEP017A Locate and rectify faults in low voltage composite appliances using set procedures UEENEEP024A Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply UEENEEP025A Attach cords, cables and plugs to electrical equipment for connection to 1000 Va.c. or 1500 Vd.c. supply |
UEENEEK145A | Implement and monitor energy sector environmental and sustainable policies and procedures | There are no prerequisite competencies for this unit |
BSBINM501A | Manage an information or knowledge management system | There are no prerequisite competencies for this unit |
UEENEEJ132A | Design commercial refrigeration systems and select components | UEENEEJ129A Establish heat loads for commercial refrigeration and/or air conditioning applicationsUEENEEJ165A Evaluate thermodynamic and fluid parameters of refrigeration systemsUEENEEJ127A Establish the thermodynamic parameters of refrigeration and air conditioning systemsUEENEEJ164A Analyse the operation of HVAC air and hydronic systemsUEENEEJ192A Analyse the psychrometric performance of HVAC/R systemsandUEENEEJ193A Analyse the thermodynamic performance of HVAC/R systemsor UEENEEJ109A UEENEEE101A UEENEEE102A UEENEEE003B UEENEEE105A UEENEEE107A UEENEEE137A UEENEEJ102A UEENEEJ103A UEENEEJ104A UEENEEJ106A UEENEEJ107A UEENEEJ108A UEENEEJ110A UEENEEJ111A UEENEEJ113A UEENEEJ153A UEENEEJ170A UEENEEJ194A UEENEEP012A UEENEEP017A UEENEEP024A UEENEEP025A |
UEENEEJ138A | Analyse vibration and noise in refrigeration and air conditioning systems | UEENEEJ165A: Evaluate thermodynamic and fluid parameters of refrigeration systems UEENEEJ164A Analyse the operation of HVAC air and hydronic systems UEENEEJ192A Analyse the psychrometric performance of HVAC/R systems and UEENEEJ193A Analyse the thermodynamic performance of HVAC/R systems or UEENEEJ109A Verify functionality and compliance of refrigeration and air conditioning installations UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace UEENEEE102A Fabricate, assemble and dismantle utilities industry components UEENEEE003B Solve problems in extra-low voltage single path circuits UEENEEE105A Fix and secure electrotechnology equipment UEENEEE107A Use drawings, diagrams, schedules, standards, codes and specifications UEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology work UEENEEJ102A Prepare and connect refrigerant tubing and fittings UEENEEJ103A Establish the basic operating conditions of vapour compression systems UEENEEJ104A Establish the basic operating conditions of air conditioning systems UEENEEJ106A Install refrigerant pipe work, flow controls and accessories UEENEEJ107A Install air conditioning and refrigeration systems, major components and associated equipment UEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerants UEENEEJ110A Select refrigerant piping, accessories and associated controls UEENEEJ111A Diagnose and rectify faults in air conditioning and refrigeration systems and components UEENEEJ113A Commission air conditioning and refrigeration systems UEENEEJ153A Find and rectify faults motors and associated controls in refrigeration and air conditioning systems UEENEEJ170A Diagnose and rectify faults in air conditioning and refrigeration control systems UEENEEJ194A Solve problems in low voltage refrigeration circuits UEENEEP012A Disconnect / reconnect composite appliances connected to low voltage installation wiring UEENEEP017A Locate and rectify faults in low voltage composite appliances using set procedures UEENEEP024A Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply UEENEEP025A Attach cords, cables and plugs to electrical equipment for connection to 1000 Va.c. or 1500 Vd.c. supply |
UEENEEK132A | Develop strategies to address environmental and sustainability issues in the energy sector | There are no prerequisite competencies for this unit |
HANDLING/ ADMINISTRATION FEES (NON-REFUNDABLE)
$200 – (Handling Fee)
$900 – (Administration Fee for Visa Assessment for students with a dependent/family)
PLACEMENT FEE
$500 – for each qualification in Ageing Support and Community Services, unless otherwise stated.
Before commencing placement within Diana School of Community Services, students will be required to obtain mandatory documents at their own expense. Students will be notified via email on when to obtain these documents. More information on these mandatory required documents can be identified on each individual course page on our website: https://aibtglobal.edu.au. Refund policy rules apply to Placement Fees. Please check our Refund Policy for more detailed information: https://aibtglobal.edu.au/support/student-forms/policies
OSHC FEE
International students must have adequate health insurance while in Australia.
It is a condition of your visa that you have Overseas Student Health Cover (OSHC) for the full duration of your student visa. OSHC is insurance to assist international students to meet the costs of medical and hospital care.
You can organise your own OSHC, or we can assist you, as AIBT has an agreement with Bupa, one of Australia’s major health insurance providers. For more information, please visit their website: https://www.bupa.com.au
UNDER 18’S FEE
We are partnered with Australian Homestay Network (AHN) – Australia’s Largest Homestay provider.
The homestay fee includes 3 meals and all amenities and may cost up to $350/week. Please visit https://www.homestaynetwork.org/students/pricing/ for more information about our prices in each campus location.
OTHER FEES
Additional fees will be incurred for re-enrolment, resubmission, credit transfer and certificate re-issuance. For further information, please visit the individual course page on our website: http://go.aibt.global/other-fees
OHS:
Practice in workplace and during training is subject to regulations directly related to occupational health and safety.
Ozone Protection and Synthetic Greenhouse Legislation:
The Ozone Protection and Synthetic Greenhouse Gas Legislation Amendment Bill 2003 apply to this qualification. Prior to planning the delivery of any training and/or assessment activities all legislative and regulatory requirements shall be identified and included.
https://www.legislation.gov.au/Details/C2004B01432
Electrical Authorisation Licenced Occupation of Air-conditioning and Refrigeration Mechanic:
Each state and territory has different requirements in relation to Australian context gap training and electrical authorisation for the licenced occupation of Airconditioning and Refrigeration Mechanic.
New South Wales
To apply for a refrigerant handling licence and the Provisional Tradesperson Certificate, OTSR holders wishing to work in New South Wales (NSW) must contact:
IMPORTANT: Both licences are required to work in NSW as an Airconditioning and Refrigeration Mechanic (under supervision).
Holders of a Trainee Licence and a Provisional Tradesperson Certificate must:
On successful completion of Australian context gap training and supervised employment, applicants are eligible to apply for a Advanced Diploma of Air-conditioning and Refrigeration Engineering (UEE62511).
On receipt of the Advanced Diploma of Air-conditioning and Refrigeration Engineering (UEE62511), an applicant may apply for a full Refrigerant Handling Licence – Qualified Persons (2 years) with ARC and an Airconditioning and Refrigeration Licence or Certificate with New South Wales Fair Trading.
For specific information about Airconditioning and refrigeration licences in NSW please contact the following:
Australian Refrigeration Council
Telephone | 1300 884 483 |
enquire@arctick.org | |
Address | Locked Bag 3033 BOX HILL VIC 3128 |
Website | https://www.arctick.org |
New South Wales Fair Trading
Telephone | 13 32 20 |
HBLicensing@finance.nsw.gov.au | |
Address | NSW Fair Trading PO Box 972 PARRAMATTA NSW 2124 |
Website | NSW Fair Trading |
Queensland
Refrigerant handling licence
To apply for a refrigerant handling licence, OTSR holders wishing to work in Queensland (QLD) must contact the:
Holders of a Trainee Licence must:
On successful completion of Australian context gap training and supervised employment, applicants are eligible to apply for a Advance Diploma of Air-conditioning and Refrigeration Engineering (UEE62511).
On receipt of the Advance Diploma of Air-conditioning and Refrigeration Engineering (UEE62511), an applicant may apply for a full Refrigerant Handling Licence – Qualified Persons (2 years).
For more information about airconditioning and refrigeration licences in QLD, please contact the Australian Refrigeration Council.
Telephone | 1300 884 483 |
enquire@arctick.org | |
Address | Locked Bag 3033 BOX HILL VIC 3128 |
Website | https://www.arctick.org |
Electrical work licence
A person who holds an OTSR as an airconditioning and refrigeration mechanic must obtain the Advanced Diploma of Air-conditioning and Refrigeration Engineering (UEE62511) before being eligible for a restricted electrical work licence in Queensland. Whilst holding the OTSR and the Trainee Licence, you must have a licensed person carry out the disconnecting, reconnecting and fault finding of any electrical equipment you are required to work on.
On receipt of the Advanced Diploma of Air-conditioning and Refrigeration Engineering (UEE62511), you may apply for a restricted electrical work licence. In most cases applicants will be issued with an electrical work training permit and will need to undertake additional on and off the job training to obtain the licence. For more information please contact the Electrical Safety Office on 1300 632 993.
Refrigeration and Airconditioning work licence
A holder of a Advanced Diploma of Air-conditioning and Refrigeration Engineering (UEE62511) and a Refrigerant Handling Licence issued by the ARC is required to apply to the Queensland Building and Construction Commission (QBCC) for licensing for refrigeration and airconditioning work. For more information please visit the QBCC website www.qbcc.qld.gov.au or contact QBCC on 139 333.
Unit Code | Unit Title | Licensing/Regulatory Information |
UEENEEED104A | Use engineering applications software on personal computers | The skills and knowledge described in this unit do not require a license to practice in the workplace. However, practice in this unit is subject to regulations directly related to occupational health and safety. |
UEENEEE038B | Participate in development and follow a personal competency development plan | The skills and knowledge described in this unit do not require a license to practice in the workplace. However, practice in this unit is subject to regulations directly related to occupational health and safety. |
UEENEEE101A | Apply Occupational Health and Safety regulations, codes and practices in the workplace | During Training: Competency development activities are subject to regulations directly related to licencing, occupational health and safety. In the workplace: The application of the skills and knowledge described in this unit require a license to practice in the workplace where work is carried out on electrical equipment or installations which are designed to operate at voltages greater than 50 V a.c. or 120 V d.c. Other conditions may apply under State and Territory legislative and regulatory requirements. |
UEENEEE102A | Fabricate, assemble and dismantle utilities industry components | During Training: Competency development activities are subject to regulations directly related to licencing, occupational health and safety. In the workplace: The application of the skills and knowledge described in this unit require a license to practice in the workplace where work is carried out on electrical equipment or installations which are designed to operate at voltages greater than 50 V a.c. or 120 V d.c. Other conditions may apply under State and Territory legislative and regulatory requirements. |
UEENEEE103A | Solve problems in ELV single path circuits | The skills and knowledge described in this unit do not require a license to practice in the workplace. However, they are subject to regulations directly related to occupational health and safety. |
UEENEEE105A | Fix and secure electrotechnology equipment | During Training: Competency development activities are subject to regulations directly related to licencing, occupational health and safety. In the workplace: The application of the skills and knowledge described in this unit require a license to practice in the workplace where work is carried out on electrical equipment or installations which are designed to operate at voltages greater than 50 V a.c. or 120 V d.c. Other conditions may apply under State and Territory legislative and regulatory requirements. |
UEENEEE107A | Use drawings, diagrams, schedules, standards, codes and specifications | During Training: Competency development activities are subject to regulations directly related to licencing, occupational health and safety. In the workplace: The application of the skills and knowledge described in this unit require a license to practice in the workplace where work is carried out on electrical equipment or installations which are designed to operate at voltages greater than 50 V a.c. or 120 V d.c. Other conditions may apply under State and Territory legislative and regulatory requirements. |
UEENEEE117A | Implement and monitor energy sector OHS policies and procedures | The competency described in this unit does not directly require a license to practice but is subject to regulations for occupational health and safety. |
UEENEEE124A | Compile and produce an energy sector detailed report | The skills and knowledge described in this unit do not require a license to practice in the workplace. However, practice in this unit is subject to regulations directly related to occupational health and safety. |
UEENEEE137A | Document and apply measures to control OHS risks associated with electrotechnology work | During Training: Competency development activities are subject to regulations directly related to licencing, occupational health and safety. In the workplace: The application of the skills and knowledge described in this unit require a license to practice in the workplace where work is carried out on electrical equipment or installations which are designed to operate at voltages greater than 50 V a.c. or 120 V d.c. Other conditions may apply under State and Territory legislative and regulatory requirements. |
UEENEEJ102A | Prepare and connect refrigerant tubing and fittings | The skills and knowledge described in this unit may, in some jurisdictions, require a license to practice in the workplace subject to regulations for undertaking refrigeration and air conditioning work. Practice in workplace and during training is also subject to regulations directly related to occupational health and safety. Note: 2. Compliance may be required in various jurisdictions relating to currency in First Aid, confined space, lifting and risk safety measures. |
UEENEEJ103A | Establish the basic operating conditions of vapour compression systems | The skills and knowledge described in this unit may, in some jurisdictions, require a license to practice in the workplace subject to regulations for undertaking refrigeration and air conditioning work. Practice in workplace and during training is also subject to regulations directly related to occupational health and safety. Note: 1. Compliance with permits may be required in various jurisdictions and typically relates to the operation of plant, machinery and equipment such as elevating work platforms, powder operated fixing tools, power operated tools, vehicles, road signage and traffic control, lifting equipment. Permits may also be required for some work environments such as confined spaces, working aloft, near live electrical apparatus and site rehabilitation. 2. Compliance may be required in various jurisdictions relating to currency in First Aid, confined space, lifting and risk safety measures. |
UEENEEJ104A | Establish the basic operating conditions of air conditioning systems | The skills and knowledge described in this unit may, in some jurisdictions, require a license to practice in the workplace subject to regulations for undertaking refrigeration and air conditioning work. Practice in workplace and during training is also subject to regulations directly related to occupational health and safety. Note: 1. Compliance with permits may be required in various jurisdictions and typically relates to the operation of plant, machinery and equipment such as elevating work platforms, powder operated fixing tools, power operated tools, vehicles, road signage and traffic control, lifting equipment. Permits may also be required for some work environments such as confined spaces, working aloft, near live electrical apparatus and site rehabilitation. 2. Compliance may be required in various jurisdictions relating to currency in First Aid, confined space, lifting and risk safety measures. |
UEENEEJ106A | Install refrigerant pipe work, flow controls and accessories | The skills and knowledge described in this unit may, in some jurisdictions, require a license to practice in the workplace subject to regulations for undertaking refrigeration and air conditioning work. Practice in workplace and during training is also subject to regulations directly related to occupational health and safety. Note: 1. Compliance with permits may be required in various jurisdictions and typically relates to the operation of plant, machinery and equipment such as elevating work platforms, powder operated fixing tools, power operated tools, vehicles, road signage and traffic control, lifting equipment. Permits may also be required for some work environments such as confined spaces, working aloft, near live electrical apparatus and site rehabilitation. 2. Compliance may be required in various jurisdictions relating to currency in First Aid, confined space, lifting and risk safety measures. |
UEENEEJ107A | Install air conditioning and refrigeration systems, major components and associated equipment | The skills and knowledge described in this unit may, in some jurisdictions, require a license to practice in the workplace subject to regulations for undertaking refrigeration and air conditioning work. Practice in workplace and during training is also subject to regulations directly related to occupational health and safety. Note: |
UEENEEJ108A | Recover, pressure test, evacuate, charge and leak test refrigerants | The skills and knowledge described in this unit may, in some States/Territories, require a license to practice in the workplace subject to regulations for undertaking refrigeration and air conditioning work. Practice in workplace and during training is also subject to regulations directly related to occupational health and safety. Note: 2. Compliance may be required in various jurisdictions relating to currency in First Aid, confined space, lifting and risk safety measures. |
UEENEEJ109A | Verify functionality and compliance of refrigeration and air conditioning installations | The skills and knowledge described in this unit require a license to practice in the workplace where plant and equipment operate at voltage above 50 V a.c. or 120 V d.c. In some States/Territories a licence is required to practise this unit in the workplace subject to regulations for undertaking refrigeration and air conditioning work and in particular working with refrigerants. Practice in workplace and during training is also subject to regulations directly related to occupational health and safety. |
UEENEEJ110A | Select refrigerant piping, accessories and associated controls | The skills and knowledge described in this unit do not require a license to practice in the workplace. However, practice in this unit is subject to regulations directly related to occupational health and safety. Note: 2. Compliance may be required in various jurisdictions relating to currency in First Aid, confined space, lifting and risk safety measures. |
UEENEEJ111A | Diagnose and rectify faults in air conditioning and refrigeration systems and components | The skills and knowledge described in this unit require a license to practice in the workplace where plant and equipment operate at voltage above 50 V a.c. or 120 V d.c. In some States/Territories a licence is required to practise this unit in the workplace subject to regulations for undertaking refrigeration and air conditioning work and in particular working with refrigerants. Practice in workplace and during training is also subject to regulations directly related to occupational health and safety. Note: 2. Compliance may be required in various jurisdictions relating to currency in First Aid, confined space, lifting and risk safety measures. |
UEENEEJ113A | Commission air conditioning and refrigeration systems | The skills and knowledge described in this unit require a license to practice in the workplace where plant and equipment operate at voltage above 50 V a.c. However other conditions may apply in some jurisdictions subject to regulations related to electrical work. Practice in the workplace and during training is also subject to regulations directly related to occupational health and safety. Note: 2. Compliance may be required in various jurisdictions relating to currency in First Aid, confined space, lifting and risk safety measures. |
UEENEEJ127A | Establish the thermodynamic parameters of refrigeration and air conditioning systems | The skills and knowledge described in this unit require a license to practice in the workplace where plant and equipment operate at voltage above 50 V a.c. or 120 V d.c. In some States/Territories a licence is required to practise this unit in the workplace subject to regulations for undertaking refrigeration and air conditioning work and in particular working with refrigerants. Practice in workplace and during training is also subject to regulations directly related to occupational health and safety. Note: |
UEENEEJ128A | Produce HVAC/R system design drawings | The skills and knowledge described in this unit require a license to practice in the workplace where plant and equipment operate at voltage above 50 V a.c. or 120 V d.c. In some States/Territories a licence is required to practise this unit in the workplace subject to regulations for undertaking refrigeration and air conditioning work and in particular working with refrigerants. Practice in workplace and during training is also subject to regulations directly related to occupational health and safety . Note: |
UEENEEJ129A | Establish heat loads for commercial refrigeration and/or air conditioning applications | The skills and knowledge described in this unit require a license to practice in the workplace where plant and equipment operate at voltage above 50 V a.c. or 120 V d.c. In some States/Territories a licence is required to practise this unit in the workplace subject to regulations for undertaking refrigeration and air conditioning work and in particular working with refrigerants. Practice in workplace and during training is also subject to regulations directly related to occupational health and safety. Note: |
UEENEEJ32A | Design commercial refrigeration systems and select components | The skills and knowledge described in this unit do not require a license to practice in the work place. However practice in this unit is subject to regulations directly related to occupational health and safety. |
UEENEEJ153A | Find and rectify faults in motors and associated controls in refrigeration and air conditioning systems | The skills and knowledge described in this unit require a license to practice in the workplace where appliances are connected to fixed wiring at voltage above 50 V a.c. or 120 V d.c. In some States/Territories a licence is required to practise this unit in the workplace subject to regulations for servicing refrigeration or air conditioning appliance in particular when working with refrigerants. Practice in workplace and during training is also subject to regulations directly related to occupational health and safety. Note: 2. Compliance may be required in various jurisdictions relating to currency in First Aid, confined space, lifting and risk safety measures. |
UEENEEJ164A | Analyse the operation of HVAC air and hydronic systems | The skills and knowledge described in this unit do not require a license to practice in the workplace. However, practice in this unit is subject to regulations directly related to occupational health and safety, codes of work practice and standard work procedures related to the operation of automated machinery. |
UEENEEJ165A | Evaluate thermodynamic and fluid parameters of refrigeration systems | The skills and knowledge described in this unit may require a license to practice in the workplace subject to regulations for undertaking of refrigeration or air conditioning work. Practice in workplace and during training is also subject to regulations directly related to occupational health and safety. Note: |
UEENEEJ170A | Diagnose and rectify faults in air conditioning and refrigeration control systems | The skills and knowledge described in this unit require a license to practice in the workplace where plant and equipment operate at voltage above 50 V a.c. or 120 V d.c. In some States/Territories a licence is required to practise this unit in the workplace subject to regulations for undertaking refrigeration and air conditioning work and in particular working with refrigerants. Practice in workplace and during training is also subject to regulations directly related to occupational health and safety. Note: 2. Compliance may be required in various jurisdictions relating to currency in First Aid, confined space, lifting and risk safety measures |
UEENEEJ192A | Analyse the psychrometric performance of HVAC/R systems | The skills and knowledge described in this unit do not require a license to practice in the workplace. However, practice in this unit is subject to regulations directly related to occupational health and safety, codes of work practice and standard work procedures related to the operation of automated machinery. |
UEENEEJ194A | Solve problems in low voltage refrigeration circuits | The skills and knowledge described in this unit require a license to practice in the workplace where plant and equipment operate at voltage above 50 V a.c. or 120 V a.c. However other conditions may apply in some jurisdictions subject to regulations related to electrical work. Practice in the workplace and during training is also subject to regulations directly related to occupational health and safety. |
UEENEEK132A | Develop strategies to address environmental and sustainability issues in the energy sector | The skills and knowledge described in this unit do not require a license to practice in the workplace. However, practice in this unit is subject to regulations directly related to occupational health and safety. |
UEENEEP012A | Disconnect / reconnect composite appliances connected to low voltage installation wiring | The skills and knowledge described in this unit requires a license to practice in the workplace where plant and equipment operate at voltage above 50 V a.c. or 120 V d.c. However other conditions may apply in some jurisdictions subject to regulations related to electrical work. Practice in the workplace and during training is also subject to regulations directly related to occupational health and safety. Note: |
UEENEEP017A | Locate and rectify faults in low voltage composite appliances using set procedures | The skills and knowledge described in this unit may require a license to practice in the workplace subject to regulations for undertaking of electrical work. Practice in workplace and during training is also subject to regulations directly related to occupational health and safety. Note: |
UEENEEP024A | Attach cords and plugs to electrical equipment for connection to a single phase 230 Volt supply | The skills and knowledge described in this unit may require a license to practice in the workplace. However, practice in this unit is subject to regulations directly related to occupational health and safety. Note: |
UEENEEP025A | Attach cords, cables and plugs to electrical equipment for connection to 1000 Va.c. or 1500 Vd.c. supply | The skills and knowledge described in this unit may require a license to practice in the workplace. However, practice in this unit is subject to regulations directly related to occupational health and safety. Note: |
UEENEEJ143A | Design complex air conditioning systems and select equipment | The skills and knowledge described in this unit do not require a license to practice in the workplace. However, practice in this unit is subject to regulations directly related to occupational health and safety. |
UEENEEJ114A | Resolve problems in hydronic systems | The skills and knowledge described in this unit require a license to practice in the workplace where plant and equipment operate at voltage above 50 V a.c. However other conditions may apply in some jurisdictions subject to regulations related to electrical work. Practice in the workplace and during training is also subject to regulations directly related to occupational health and safety. Note: |
UEENEEE011C | Manage risk in electrotechnology activities | The skills and knowledge described in this unit do not require a license to practice in the workplace. However, practice in this unit is subject to regulations directly related to occupational health and safety. |
UEENEEE083A | Establish and follow a competency development plan in an electrotechnology engineering discipline | The skills and knowledge described in this unit require a licence to practise in the workplace subject to regulations for undertaking of electrical work. Practice in workplace and during training is also subject to regulations directly related to occupational health and safety. |
UEENEEJ040B | Manage refrigeration and air conditioning projects | The skills and knowledge described in this unit do not require a license to practice in the workplace. However, practice in this unit is subject to regulations directly related to occupational health and safety. |
UEENEEJ069B | Plan refrigeration and air conditioning projects | The skills and knowledge described in this unit do not require a license to practice in the workplace. However, practice in this unit is subject to regulations directly related to occupational health and safety. |
UEENEEJ138A | Analyse vibration and noise in refrigeration and air conditioning systems | The skills and knowledge described in this unit do not require a license to practice in the workplace. However, practice in this unit is subject to regulations directly related to occupational health and safety, codes of work practice and standard work procedures related to the operation of automated machinery. |
CPCCWHS1001 | Prepare to work safely in the construction industry | Licensing, legislative, regulatory or certification requirements apply to this unit. Relevant work health and safety state and territory regulatory authorities should be consulted to confirm jurisdictional requirements. |
Once the units of competency required in the training package for this qualification have been successfully completed, the student will be issued with an Advanced Diploma of Air Conditioning and Refrigeration Engineering (UEE62520) and an academic transcript of all completed units within 30 calendar days. Students who successfully complete individual units of competency within the qualification, but not the qualification in its entirety will be eligible to receive a Statement of Attainment. This document contains a record of all completed units and will be available to students by the end of their course.
AIBT does not guarantee that:
Senior Technical Officer (Refrigeration and Air-conditioning Engineering)
Refrigeration and Air-conditioning Engineer
Completion of an AIBT qualification does not guarantee an employment outcome.
This qualification will only fulfil the academic requirements, not a licensed trade qualification. For more information please visit: The Australian Refrigeration Council Ltd (ARC).
Australia Institute of Business and Technology acknowledges and pays respect to the past and present Traditional Custodians and Elders of this nation and the continuation of cultural, spiritual and educational practices of Aboriginal and Torres Strait Islander peoples.